To provide for single dwellings and semi-detached dwellings on lots designated for low density residential development.
Subject to any fundamental use criteria for certain uses set out below, the permitted uses and the discretionary uses for this zone are listed in Table 12.8(A).
Permitted uses
Discretionary uses
Deleted (Bylaw 51-2024)
Home business minor*
Residential sales centre*
Single dwelling
Subdivision must comply with Table 12.8(B).
Table 12.8(B) Subdivision Regulations
Subsection
Regulation
Measurement
(a)
Minimum lot width for an interior lot
10.4 m
(b)
Minimum lot width for a corner lot
13.0 m
(c)
Minimum lot area
350 m2
Development must comply with Table 12.8(C), Table 12.8(D), and Table 12.8(E).
Table 12.8(C) Development Regulations: Principal Building
Height
Maximum height
9.1 m
Maximum height when located on a lot within the Urban Service Area where an Area Structure Plan or Area Structure Plan amendment was approved after January 1, 2014
10.5 m
Minimum setbacks
From a front lot line
6.0 m
(d)
From a front lot line when located on a lot within the Urban Service Area where an Area Structure Plan or Area Structure Plan amendment was approved after January 1, 2014
5.5 m
(e)
From a front lot line where vehicular access to the lot is from a rear lane
4.5 m
(f)
From a lot line to the vehicle door of an attached garage where it faces a road or a lane
(g)
From a side lot line
1.2 m
(h)
From a side lot line abutting a flanking road (Bylaw 30-2025)
3.0 m
(i)
From a side lot line abutting a lot(s) with zoning that allows for multi-unit residential, commercial or industrial development
(j)
From one side lot line when there is no direct vehicular access to the rear yard or to an attached garage
(k)
From one side lot line on a lot registered prior to July 3, 2001 where:
0.0 m
(l)
From a rear lot line on an interior lot
7.5 m
(m)
From a rear lot line on a corner lot
Exposed building frontage
(n)
Minimum building frontage of the first storey of the dwelling, excluding an attached garage, exposed to the road
1.8 m
Attached garage width
(o)
Maximum width
7.32 m
(p)
Maximum width where articulation or architectural features are provided to differentiate the increased width from the portion of the garage façade containing the vehicle door
8.82 m
(q)
Maximum width when located within Phase 2 of the Salisbury Village Area Structure Plan
7.93 m
(r)
The vehicle door(s) of an attached garage should be sited parallel to the front lot line.
Table 12.8(D) Development Regulations: Accessory Buildings and Accessory Structures
(a.1)
(Bylaw 45-2024)
1.5 storeys (1 storey and a loft) and 6.5 m (Bylaw 30-2025)
18.0 m
1.0 m
From a rear lot line
From a lot line to the vehicle door of a garage where it faces a lane or road
Maximum ground floor area
Of all accessory buildings combined
52 m2
Table 12.8(E) Development Regulations: Site Coverage
Maximum site coverage
42.5%
Last updated: Friday, August 22, 2025 Page ID: 51958